Fumonisins fluorescence
quantitative rapid test card
Catalog No.: IF005A01
[Brief]
This product is used for rapid quantitative
detection of Fumonisins in grains and their products, feed raw materials, and
some finished feed products. It is suitable for on-site rapid detection by
various enterprises, grain depots, testing institutions, and government
regulatory departments.
[Principle]
This product is based on the principle of
competition and combined with fluorescence chromatography technology. The
Fumonisins (FUM) in the sample competes with the FUM-Ag coated on the NC
membrane testing line for fluorescent microsphere labeled FUM monoclonal
antibody. As the FUM content in the test sample increases, the amount of
fluorescent microsphere antibody complex bound to the testing line decreases,
and the fluorescence intensity of the testing line weakens accordingly. After
the reaction is completed, the content of FUM in the sample can be detected
using a matching handheld fluorescence immunoassay analyzer.
[Application]
Grains and their products, feed raw materials,
and some finished feed products.
[Specification]
20 tests/box; 50 tests/box
[Product performance]
Detection range: 0~12000μg/kg(ppb)
Detection limit: 250μg/kg(ppb)
Recovery rate: 80%~120%
[Components]
|
Components
|
Quantity
|
1
|
FUM test card
|
20T/box
|
50T/box
|
|
2
|
Sample diluent
|
1bottle, 25mL/bottle
|
2bottle, 25mL/bottle
|
|
3
|
ID card
|
1piece
|
1piece
|
|
4
|
Instructions
|
1piece
|
1piece
|
|
[Required equipment, consumables, and reagents] (Not provided)
1. Equipment and consumables: electronic
balance, oscillator, centrifuge, pipette, and tips (20-200μL,100-1000μL,
1-5mL), centrifuge tube (50mL, 1.5mL), disposable gloves and mask.
2. Reagent: Anhydrous ethanol (AR).
[Reagent preparation]
Sample extraction solution: Take 500mL of
anhydrous ethanol and add 500mL of pure water, mix well for usage.
[Experimental Steps]
1. Preparation before testing
a. Return the test card and sample diluent to room temperature (25℃) for at least 30 minutes.
b. Turn on the power of the fluorescence immunoassay analyzer, preheat for
10 minutes.
c. Turn on the constant temperature timer, set the incubation temperature
to 37 ℃ and the incubation time
to 8 minutes.
2. Sample preparation
Multiple point sampling is required for the test
sample, with a total sampling amount of 300-500g. After thorough mixing, the
particles can be homogenized to over 90% and pass through a 20 mesh sieve.
Extract the screened samples for testing.
a. Conventional samples
Weigh 5.0±0.05g of homogeneous sieved sample
into a 50mL centrifuge tube, add 25mL of sample extraction solution, shake for
3 minutes, and centrifuge at 4000rpm for 5 minutes. Take 50μL supernatant, add
750μL sample diluent, shake and
mix well for 10 seconds, ready for testing.
b. Bran sample (strong water absorbing sample)
Weigh 2.5±0.025g of homogeneous sieved
sample into a 50mL centrifuge tube, add 25mL of sample extraction solution,
shake for 3 minutes, and centrifuge at 4000rpm for 5 minutes. Take 50μL
supernatant, add 750μL sample diluent,
shake and mix well for 10 seconds, ready for testing. (In this case,
multiplying the test result by 2 is the final concentration)
Note: When the concentration of the analyte in
the sample exceeds the range of the curve, the sample extraction solution can
be used to dilute the extracted supernatant by 2-5 times, then take 50μL
diluted extraction solution, add 750μL sample
diluent, mix thoroughly and add the sample for testing. The final result
is obtained by multiplying dilution factor.
3. Sample testing
a. Take out the warmed test card from the aluminum foil bag, place it on a
horizontal table, and use a pipette to aspirate 70μL of the diluted sample, add
into the sample hole, insert the test card into the constant temperature
timer socket, and incubate for 8 minutes;
b. Insert the ID card of the corresponding project and batch into the fluorescence
immunoassay analyzer and read the ID card information;
c. After incubation, select the sample type (standard curve) corresponding
to the test sample, insert the test card into the fluorescence immunoassay
analyzer (see the manual of analyzer for specific operation), and click
"Test" to perform the testing.
Note: During testing, do not point the
constant temperature timer socket towards the air conditioner or fan vent.
Sample type corresponding to sample kind (standard curve)
Sample kind (standard curve)
|
Applicable sample types
|
Sample kind 1
|
Samples and processed products of grains such as wheat, corn, rice,
peanuts, and beans, as well as feed raw materials and some finished feed
products
|
4. Result acquisition
The test results will be displayed on the screen
of the fluorescence immunoassay analyzer. You can click to print to obtain a
paper printed report, or export an electronic version of the data report
through a data cable.
[Precautions]
1. Please use the test card within its validity
period, and each card can only be used once;
2. Please use the test card immediately when
opening the aluminum foil bag packaging;
3. Different batches of test cards, sample
diluents, and ID cards should not be mixed;
4. Do not touch the white film strip at the
detection window. If touched, please discard this card to avoid affecting the
detection results;
5. Please test immediately after incubation and
try to complete the test within 2 minutes after incubation;
6. During the testing process, reagents,
instruments, etc. should be avoided from direct sunlight, fans, and air
conditioning;
7. This product is only used for screening. If a
positive result appears, it is recommended to use national standard methods for
confirmation;
8. If you encounter any problems during testing,
please contact the supplier.
9. The disposal of experimental waste shall be
carried out in accordance with national or local laws and regulations.
[Storage and shelf life]
1. This product should be stored in a dry and
dark place at 2-8 ℃, and should not be frozen.
2. The shelf life is 12 months. The batch number
and production date can be found in the outer packaging.
Shenzhen Lvshiyuan Biotechnology Co., Ltd
D Building,
National Biological Industrial Park of Marinelife, No.2 Binhai Road, Dapeng,
Shenzhen, 518120 China
Tel.
86-755-28438788
Fax
86-755-28938800
Email: info@lsybt.com
Website: www.lsybt.com